TROUBLESHOOTING
16
TROUBLESHOOTING
SYMPTOM POSSIBLE PROBLEMS SERVICE
Returning/Purging Stage of Operation
If the TrakFast tool will not operate after following the above service directions,
return the tool to an Ramset Distributor Sales Representative for service.
800-241-5640
www.ramset.com
Tool operated and
drove fastener, but
piston did not return
to up position.
Combustion Chamber
does not drop after tool
cycles.
Built-up dirt and debris
on Piston or in Nose
bore.
Mushrooming of
Piston Tip.
Exhaust ports on the
Sleeve are dirty or
clogged.
Tool (Sleeve) or
O-Rings are dirty.
Work Contacting
Element is bent,
or tool is dirty.
Clean Piston and Nose bore with safety
solvent.
Contact Ramset Distributor Sales
Representative for service.
Return tool to Authorized Ramset Distributor
Sales Representative for service.
Clean tool per Cleaning Procedure.
Clean tool or replace Work Contacting
Element as required.